Bodaq® Fire Test Report

Surface burning characteristics test report on three Bodaq® interior film samples submitted by Hyundai L&C in July 2026, run on the Steiner tunnel method that is the technical equivalent of ASTM E84. Read it here or download the PDF for a submittal.

MethodSteiner tunnel surface burning test (ASTM E84 equivalent)
ResultWithin the Class A range on all three samples
Flame Spread Index5 to 10
Smoke Developed Index250 to 300
SamplesWood grain laminate, solid white, black laminate
Report4792081374, July 29, 2026
Bodaq® Fire Test Report, page 1 of 10 Bodaq® Fire Test Report, page 2 of 10 Bodaq® Fire Test Report, page 3 of 10 Bodaq® Fire Test Report, page 4 of 10 Bodaq® Fire Test Report, page 5 of 10 Bodaq® Fire Test Report, page 6 of 10 Bodaq® Fire Test Report, page 7 of 10 Bodaq® Fire Test Report, page 8 of 10 Bodaq® Fire Test Report, page 9 of 10 Bodaq® Fire Test Report, page 10 of 10

Class A is a Flame Spread Index of 0 to 25 with a Smoke Developed Index of 0 to 450. The laboratory did not establish a listing or classification from this project and the results apply to the samples tested. Bodaq® reports are issued per pattern series; for a series report with the pattern-code mapping for a specific finish schedule, see the Bodaq® fire ratings page.